FIBRINOLYSIS EXPLORE PLASMINOGEN ACTIVATOR INHIBITORS
PLASMINOGEN ACTIVATOR INHIBITOR-1: PAI-1
ZYMUTEST™ PAI-1 Activity Measurement of the activity of human Tissue-Plasminogen Activator Inhibitor, type I (PAI-1), in plasma, by Bio-Immuno-Assay.
COMPLETE SOLUTION Product Name RS Ref. Presentation ZYMUTEST™ PAI-1 Activity RUO RK019A 96 tests
THROMBIN ACTIVATABLE FIBRINOLYSIS INHIBITOR: TAFI
ZYMUTEST™ (Total) TAFI:Ag Measurement of human Total TAFI (Thrombin Activatable Fibrinolysis Inhibitor) antigen forms in plasma. Zymogen, as well as inactive forms are measured, by Elisa.
COMPLETE SOLUTION Product Name RS Ref. Presentation ZYMUTEST™ (Total) TAFI:Ag RUO RK008A on-demand 96 tests
ZYMUTEST™ (Activatable) TAFI Measurement of human TAFI (Thrombin Activatable Fibrinolysis Inhibitor) zymogen and fully activatable (or CPU), in plasma. Inactive forms of TAFI are measured, by Elisa.
COMPLETE SOLUTION Product Name RS Ref. Presentation ZYMUTEST™ (Activatable) TAFI RUO RK037A on-demand 96 tests
EXPLORE PLASMINOGEN ACTIVATORS
Tissue plasminogen activator tPA
ZYMUPHEN™ tPA Activity Measurement of tPA activity in human acidified citrated plasma, using a Bio-Immuno-Assay.
COMPLETE SOLUTION Product Name RS Ref. Presentation ZYMUPHEN™ tPA Activity RUO 521296 on-demand 96 tests
MONITORING ANTICOAGULANT
BIOPHEN™ HEPARIN (AT+) Kinetics assay for measuring the concentration of heparin, and heparin-like anticoagulants, in human citrated plasma or in any other biological fluid, using an anti-Xa chromogenic method, with the addition of Antithrombin (AT), when endogenous AT concentration is insufficient for measuring heparin.
REAGENT CALIBRATORS CONTROLS Product Name RS Ref. Presentation Product Name Ref. Product Name Ref.
BIOPHEN™ HEPARIN (AT+) RUO 221007
R1: 2 x 7.5 mL BIOPHEN™ UFH Calibrator
BIOPHEN™ Heparin Calibrator
BIOPHEN™ Arixtra® Calibrator
222301
222001
222501
BIOPHEN™ UFH Control Plasma
BIOPHEN™ LMWH Control Plasma
BIOPHEN™ LMWH Control Low
BIOPHEN™ Arixtra® Control Plasma
223101
223001
223701
224001
R2: 2 x 7.5 mL
R3: 2 x 2.5 mL
BIOPHEN™ ANTI-Xa (2 Stages Heparin Assay) Two stages chromogenic anti-Xa method for measuring the activity of heparins (UFH or LMWH), in presence of a constant amount of AT, in compliance with Pharmacopeias. This method can be used for testing heparin in human citrated plasma, or in purified solutions.
REAGENT CALIBRATORS CONTROLS Product Name RS Ref. Presentation Product Name Ref. Product Name Ref.
BIOPHEN™ ANTI-Xa (2 Stages Heparin Assay)
RUO 221005
R1: 2 x 1 mL BIOPHEN™ UFH Calibrator
BIOPHEN™ Heparin Calibrator
222301
222001
BIOPHEN™ UFH Control Plasma
BIOPHEN™ LMWH Control Plasma
BIOPHEN™ LMWH Control Low
223101
223001
223701
R2: 2 x 1 mL
R3: 2 x 1 mL
BIOPHEN™ ANTI-IIa (2 Stages Heparin Assay) Two stages chromogenic anti-IIa assay for measuring the activity of heparins (UFH or LMWH), in presence of a constant amount of AT, in compliance with Pharmacopeias. This method can be used for testing heparin in human citrated plasma, or in purified solutions.
REAGENT CALIBRATOR CONTROL Product Name RS Ref. Presentation Product Name Ref. Product Name Ref.
BIOPHEN™ ANTI-IIa (2 Stages Heparin Assay)
RUO 220005
R1: 2 x 1 mL BIOPHEN™ UFH
Calibrator 222301 BIOPHEN™ UFH
Control Plasma 223101R2: 2 x 1 mL
R3: 2 x 1 mL
BIOPHEN™ HEPARIN ANTI-IIa (kinetics) One stage, kinetics anti-IIa method for measuring the concentration of heparin, and heparin-like anticoagulants. This method is proposed for testing heparin in buffer, or purified systems. Not suitable for testing plasma.
REAGENT CALIBRATOR CONTROL Product Name RS Ref. Presentation Product Name Ref. Product Name Ref.
BIOPHEN™ Heparin ANTI-IIa (kinetics)
RUO 221020
R1: 2 x 5 mL
- - - - R2: 2 x 10 mL R3: 2 x 10 mL R4: 2 x 20 mL
GL OB
AL &
RO UT
IN E
TE ST
S FI
BR IN
OL YS
IS TH
RO M
BO PH
IL IA
RE SE
AR CH
PR IM
AR Y
HE M
OS TA
SI S
CA LI
BR AT
OR S
& CO
NT RO
LS IN
DE X
M ON
IT OR
IN G
AN TI
CO AG
UL AN
T AU
XI LI
AR Y
RE AG
EN TS
BL EE
DI NG
DI
SO RD
ER S
101 100