PROTHROMBIN TIME (PT)(1)
PT explores the coagulation extrinsic pathway and can be used for investigating some congenital or acquired bleeding disorders, liver diseases, vitamin K deficiency and vitamin K antagonists therapy. It allows exploration of so-called vitamin K dependent coagulation factors. This is the most widely used coagulation assay for laboratory monitoring of anticoagulant therapy with Vitamin K Antagonists (VKA).
PT Phen™ Determination of prothrombin time (PT).
REAGENT CALIBRATORS CONTROLS Product Name RS Ref. Presentation Product Name Ref. Product Name Ref.
(h)PT-Phen™ CE-IVD
CK581 12 x 4 mL PT Calibrator Set
EASYPLASMA™ Calibrator
SC084K
226601
BIOPHEN™ Normal Control Plasma
BIOPHEN™ Abnormal Control Plasma
EASYPLASMA™ Control Set
223201
223301
225601 CK582 12 x 8 mL
CK583 12 x 18 mL
PT-Phen™ LRT Liquid and Ready to use
CE-IVD
CK584K 6 x 5 mL
PT Calibrator Set SC084K
BIOPHEN™ Normal Control Plasma
BIOPHEN™ Abnormal Control Plasma
EASYPLASMA™ Control Set
223201
223301
225601
CK584L 12 x 5 mL
CK586K 6 x 20 mL
CK586L 12 x 20 mL
ACTIVATED PARTIAL THROMBOPLASTIN TIME (aPTT)(1)
Explores the intrinsic pathway of coagulation and is a screening test to investigate some congenital or acquired deficiencies, especially hemophilia A and B, or coagulation inhibitors such as Lupus Anticoagulant (LA) or autoantibodies against coagulation factors.
CEPHEN™ Determination of aPTT.
REAGENT CALIBRATOR CONTROLS Product Name RS Ref. Presentation Product Name Ref. Product Name Ref.
CEPHEN™ Liquid aPTT Ready to use
CE-IVD
CK511K 6 x 1 mL
- -
LA Control Plasma LA Control Plasma
Weak LA Control Plasma
High BIOPHEN™ Normal
Control Plasma BIOPHEN™ Abnormal
Control Plasma EASYPLASMA™
Control Set
SC081K SC082K
SC083K
223201
223301
225601
CK512K 6 x 2.5 mL
CK515K 8 x 5 mL
CK515L 12 x 5 mL
CEPHEN™ LS Determination of aPTT. This reagent offers a good sensitivity to the presence of LA.
REAGENT CALIBRATOR CONTROLS Product Name RS Ref. Presentation Product Name Ref. Product Name Ref.
CEPHEN™ LS Liquid aPTT Lupus sensitive Ready to use
CE-IVD
CK521K 6 x 1 mL
- -
LA Control Plasma LA Control Plasma
Weak LA Control Plasma
High BIOPHEN™ Normal
Control Plasma BIOPHEN™ Abnormal
Control Plasma EASYPLASMA™
Control Set
SC081K SC082K
SC083K
223201
223301
225601 CK522K 6 x 2.5 mL
FIBRINOGEN(1)
Elevated fibrinogen concentrations are observed in inflammation and have also been considered as a risk factor for cardiovascular disease and thrombosis. Hypofibrinogenemia can be present in patients with fibrinogen deficiency or dysfunction (abnormal protein), and is also associated with severe liver diseases, or excessive consumption (Disseminated Intravascular Coagulation (DIC)). Numerous variants of fibrinogen have been described, and are associated to asymptomatic cases or hypofibrinogenemia, with clinical manifestations of bleeding, or thrombosis (resulting from an impaired fibrinolysis).
FIBRIPHEN™ Measurement of the fibrinogen concentration in plasma using the von Clauss method. This reagent is available with the lyophilized presentation, or the ready to use liquid format.
REAGENT CALIBRATORS CONTROLS Product Name RS Ref. Presentation Product Name Ref. Product Name Ref.
FIBRIPHEN™ LRT Liquid and Ready to use
CE-IVD CK585K 6 x 5 mL
BIOPHEN™ Plasma Calibrator
EASYPLASMA™ Calibrator
222101
226601
BIOPHEN™ Normal Control Plasma
BIOPHEN™ Abnormal Control Plasma
EASYPLASMA™ Control Set
223201
223301
225601
FIBRIPHEN™ CE-IVD
CK571K 6 x 1 mL BIOPHEN™ Plasma Calibrator
EASYPLASMA™ Calibrator
222101
226601
BIOPHEN™ Normal Control Plasma
BIOPHEN™ Abnormal Control Plasma
EASYPLASMA™ Control Set
223201
223301
225601
CK572K 6 x 2 mL
CK575K 8 x 5 mL
(1) cf Dedicated intructions for use (1) cf Dedicated intructions for use
GL OB
AL &
RO UT
IN E
TE ST
S FI
BR IN
OL YS
IS TH
RO M
BO PH
IL IA
RE SE
AR CH
PR IM
AR Y
HE M
OS TA
SI S
CA LI
BR AT
OR S
& CO
NT RO
LS IN
DE X
M ON
IT OR
IN G
AN TI
CO AG
UL AN
T AU
XI LI
AR Y
RE AG
EN TS
BL EE
DI NG
DI
SO RD
ER S
13 12